Command : WUBE Function : BEEP SETTING Command category: WRITE
Parameter : 1 ~ 7
Example : WUBE6<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter: 1 = Emit “click” when key is pressed.
2 = Emit “click” when key entry is ignored.
3 = Beep when correct entry is made.
4 = Beep when entry data is out of range.
5 = Beep when key entry is cancelled.
6 = Beep when On/Off parameter is set to ON.
7 = Beep when On/Off parameter is set to OFF.
Data entry for out of range will respond by ?<CR><LF>, and the command will be ignored.
General information
The following commands are used only during production of the SDU5600 to assist testing, and
therefore, the commands are given for completeness only.
Command : RVIM Function : READ VISUAL IMAGE Command category: READ
Parameter : N/A
Example : RVIM<CR><LF> Response:
see remarks
Remarks: When this command is sent to the SDU5600, it will respond as follows:
1 Respond to the command by sending <SP><CR><LF> to PC.
2. Wait for approximately 400 mS.
3. Change baud rate to 115200bps automatically.
4. Output VIM (0x56, 0x49, 0x4d in hexadecimal).
5. Output 1 dot ( = 1 byte) of screen image data in 2 characters (in hexadecimal).
(Example) 0x4a data = 1A (2 byte) 0x31, 0x41 (in hexadecimal) 356 x 236 dot
(= 168032 characters)
6. Output X (0x58 in hexadecimal).
7. Wait for approximately 100 mS.
8. Return baud rate to 9600 bps again.
9. Output OK response <SP><CR><LF>.
Command : RIGD Function : GRAPHIC DOWNLOAD Command category: READ
Parameter : N/A
Example : RIGD<CR><LF> Response:
see remarks
Remarks: When this command is sent to the SDU5600, it will respond as follows producing a level
whic corresponds to each frequency across the sceen.
(Example):
========== Start from here ============
IGD<SP>CR><LF>
/<SP><CR><LF>
F5.70000, L-90<SP><CR><LF>
F5.73125, L-90<SP><CR><LF>
(Some lines omitted)
F7.73125, L-86<SP><CR><LF>
F7.76250, L-86<SP><CR><LF>
(Some lines omitted)
F15.66875, L-90<SP><CR><LF>
F15.70000, L-90<SP><CR><LF>
/<SP><CR><LF>
========== End =====================