34
6-2 Monitor the VHF FM band in the spectrum analyser mode
Continue to operate the SDU5600 from section 6-1 where the SDU5600 / AR5000A+3 has been set
in the spectrum monitoring mode.
The example to the right is the actual
result which was obtained after
monitoring the signal spectrum at the
AOR headquarters in Tokyo. It indicates
the input signal being saturated,
resulting in some weak ghost signals
appearing at regular intervals close to
the floor level of the spectrum trace.
Adjust the input sensitivity
(from -30 to -20)
Press the AMPLITUDE key to display
the reference level on the LCD, which
appears in reverse contrast (-30dBm).
Rotate the main dial to select -20dBm
which lowers the input sensitivity by
10dB followed by ENT
(MHz or kHz)
Adjust the resolution bandwidth
(from 4kHz to 128kHz)
Press the RBW key to display the
resolution bandwidth value on the LCD,
which appears in reverse contrast
(4kHz). Rotate the main dial to select
128kHz followed by ENT
(MHz or kHz)
The example on the right now shows the
same result with the RBW set to
128kHz, this bandwidth is far more
suitable for monitoring FM broadcast
signals with wider band occupancy.
Refer to page 23, section 5-4-1
should you wish to operate the
CF, frequency span, etc in the
spectrum analyser mode.