Spectrum analysis
Command : WSCF Function : SET CENTER FREQUENCY Command category: WRITE
Parameter : Min- Max (in MHz)
Example : WSCF79.5<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Frequency entry for out of receive range will be respond by ?<CR><LF>, and the
command will be ignored.
Command : RSCF Function : READ CENTER FREQUENCY Command category: READ
Parameter : N/A
Example : RSC<CR><LF> Response: SCF79.5<SP><CR><LF>
Remarks: Frequency is displayed in MHz.
Command : WSSP Function : SET SPAN FREQUENCY Command category: WRITE
Parameter : 0.16 ~ 10 (MHz)
Example : WSSP0.62<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Data entry for out of range will be respond by ?<CR><LF>, and the command will be
ignored.
Command : RSSP Function : READ SPAN FREQUENCY Command category: READ
Parameter : N/A
Example : RSSP<CR><LF> Response: SSP0.62<SP><CR><LF>
Remarks: Frequency is displayed in MHz.
Command : WSBW Function : SET RBW Command category: WRITE
Parameter : 1 ~ 4
Example : WSBW1<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter vs. RBW is as follows: 1 = 4 KHz, 2 = 32 KHz, 3 = 64 KHz, 4 = 128 KHz
Data entry for out of range will be respond by ?<CR><LF>, and the command will be ignored.
Command : RSBW Function : READ RBW Command category: READ
Parameter : N/A
Example : RSBW<CR><LF> Response: SBW4<SP><CR><LF>
Remarks: Parameter vs. RBW is as follows: 1 = 4 KHz, 2 = 32 KHz, 3 = 64 KHz, 4 = 128 KHz.
Command : WSGN Function : SET AMPLITUDE Command category: WRITE
Parameter : -30 ~ 0
Example : WSGN-30<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Amplitude is set in 10 incremental. Data entry for out of range will be respond by
?<CR><LF>, and the command will be ignored.
Command : WSCM Function : SET CURSOR Command category: WRITE
Parameter : 1 ~ 3
Example : WSCM3<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter : 1 = MARKER, 2 = PEAK, 3 = C-PEAK To use this command, you need to set
the trigger level by using the WSTL command. Data entry for out of range will be respond by
?<CR><LF>, and the command will be ignored.
Command : RSCM Function : READ CURSOR Command category: READ
Parameter : N/A
Example : RSCM<CR><LF> Response: SCM1<SP><CR><LF>
Remarks: Parameter : 1 = MARKER, 2 = PEAK, 3 = C-PEAK