AOR SDU5600 Specifications Page 37

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
37
6-5 Suitable applications of each monitoring mode
A summary of the three monitoring modes and suitable applications is given
here:
Spectrum analyser mode
This mode is the DEFAULT and most common monitoring mode among the
three. It is suited to the monitoring of permanent or intermittent signals or
noise. The CF (centre frequency) and SPAN (visible bandwidth) are the main
criteria to be specified.
Step resolution mode
This mode is suited best to monitor signals which are allocated with certain
intervals over the band spectrum. The STEP is the criteria to be specified in
place of the SPAN, so that one dot is equal to one step on the display.
Channel scope mode
This mode is best suited to monitor known channelised frequency spectrums
such as VHF airband and FM sections or broadcast and ham radio bands.
The start frequency, end frequency and step have to be specified. There is no
concept of CF applied to this mode. It is most convenient to follow and listen
to the various signals by using both marker and receive markers.