Continuous peak detection (C-Peak)
This facility is designed to continue the peak signal detection process one sweep after another.
Press the C-Peak key to activate the facility. There is no trigger level setup in the process.
To return to the instantaneous
reading either from the peak
detection mode or continuous
peak detection mode press the
CLR key... depending on the
operating configurations a multiple
press of CLR may be required.
Marker receiver (MK.F)
This facility is designed to force the
companion receiver to receive the
signal where the marker is
positioned on the screen. There
are slight variations in functionality
monitoring mode-by-mode.
MK-CF
In the
spectrum analyser mode
and
step resolution mode
the key it works as
MK > CF
(marker to centre frequency) which forces the marker frequency to become the centre frequency.
MK-RF
In the channel scope mode the key works as
MK > RF
(marker to receive frequency) where the
companion receiver will receive the marker frequency. The start frequency, channel step and end
frequency are unaffected, so will continue monitoring in the channel scope mode as configured.
MK.F key functions
Spectrum analyser mode
Step resolution mode
Channel scope mode
When the continuous peak detection is being used in the channel scope mode, the marker will
automatically move to the strongest signal detected in the process of sweep. Press the MK.F key to
automatically tune the companion receiver to the strongest signal instantly, so that you can monitor
the active frequency.
Section 5-5