Visual command
Command : WVPM Function : SET PLOT MODE Command category: WRITE
Parameter : 1 ~ 2
Example : WVPM2<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter: 1 = PAINT, 2 = OUTLINE Data entry for out of range will be respond by
?<CR><LF>, and the command will be ignored.
Command : RVPM Function : READ PLOT MODE Command category: READ
Parameter : N/A
Example : RVPM<CR><LF> Response: VPM1<SP><CR><LF>
Remarks: Parameter: 1 = PAINT, 2 = OUTLINE
Command : WVDD Function : SET F-DIR Command category: WRITE
Parameter : 1 ~ 2
Example : WVDD2<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter: 1 = NORMAL, 2 = REVERSE Data entry for out of range will be respond by
?<CR><LF>, and the command will be ignored. This command is available only when the receiver is
selected either Other(10M) or Other (45M).
Command : RVDD Function : READ F-DIR Command category: READ
Parameter : N/A
Example : RVDD<CR><LF> Response: VDD1<SP><CR><LF>
Remarks: Parameter: 1 = NORMAL, 2 = REVERSE
Command : WVWF Function : SET WATERFALL FUNCTION Command category: WRITE
Parameter : 1 ~ 2
Example : WVWF2<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter: 1 = NORMAL, 2 = WATERFALL Data entry for out of range will be respond by
?<CR><LF>, and the command will be ignored
Command : RVWF Function : READ WATERFALL FUNCTION Command category: READ
Parameter : N/A
Example : RVWF<CR><LF> Response: VWF2<SP><CR><LF>
Remarks: Parameter: 1 = NORMAL, 2 = WATERFALL
Command : RVIM Function : READ VISUAL IMAGE Command category: READ
Parameter : N/A
Example : RVIM<CR><LF> Response:
see remarks
Remarks: Due to the huge volume of image data, while this command is executed the
communication speed will be changed to 115200bps. After data read is completed, the data speed
will return to 9600 bps. A specific example of the resonse cannot be presented here due to its nature.
Section 8-4