AOR AR8200 Specifications Page 68

  • Download
  • Add to my manuals
  • Print
  • Page
    / 142
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 67
68
Use the key sequence to access the “SCAN-GROUP” menu. Use the
ï ð keys to select the SCAN-GROUP number between 1 and 9. ò three times to move down
beyond the bank link facility and onto the additional scan environment facilities: delay, level, voice, free,
mode scan.
1. DELAY OFF / 0.1 - 9.9 seconds (default 2.0s)
2. LEVEL OFF / 1 - 255 (default OFF)
3. VOICE OFF / 1 - 255 (default OFF)
4. FREE OFF / 1 - 60 seconds (default OFF)
5. MODE ALL, WFM, NFM, SFM, WAM, AM, NAM, USB, LSB, CW
7-8-1 Scan DELAY
The scan DELAY parameter affects the time the AR8200 will remain on an active frequency in scan
mode once the received signal has disappeared and the squelch has closed. This is particularly useful
for customising how long the receiver will wait for a reply before resuming scan. For example, when
communications are passed back and forth between a control tower / aircraft which may take a few
seconds. The limits are OFF and 0.1 to 9.9 seconds in 0.1s increments (default 2.0 seconds).
Scan DELAY is configured via the SCAN-GROUP menu. Use the key sequence
to access the “SCAN-GROUP” menu. Use the ï ð keys to select the SCAN-GROUP
number between 1 and 9. ò three times to display the scan environment parameters starting
with the DELAY.
to toggle the status between 2.0s and OFF,
the default is 2.0s. Use the main dial to increment delay time in
0.1s or the ï ð keys to increment in 1.0s.
2.0s The AR8200 will wait the specified time after the
squelch closes before scan.
OFF The AR8200 will resume scan instantaneously
when the squelch closes.
to accept the changes and return to the display prior to accessing the SCAN
environment menu. Alternatively you may move to the next option (scan LEVEL squelch) by pressing
the ò key.
7-8-2 Scan LEVEL
The scan LEVEL squelch parameter causes the AR8200 to check the signal strength and to only open
the squelch when the signal strength is above the stated level (which is programmable in 256 steps).
The limits are OFF and 1 to 255 (default off).
Scan LEVEL is configured via the SCAN-GROUP menu. Use the key sequence
to access the “SCAN-GROUP” menu.
Section 7-8, 7-8-1, 7-8-2
Page view 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 141 142

Comments to this Manuals

No comments