FAST RADIO MODEM ARD9900 Multi-Mode And Digital Voice Interface Instruction Manual AOR LTD. Authority On Radio commu
Top Panel s. Internal speaker Internal View t. Factory setting jumper (JP 8) Must be set be
x. Output level setting (JP 10) Jumper setting 1 - 2 Normal level (default) (LOW) 2 - 3
Interfacing the ARD9900 Connection to a Radio Before using your ARD9900, you will first need to wire the cable between your radio equipment and t
Microphone connector of the ARD9900: Pin Function Description 1. Speaker output Monitor output signal is present at this pin when the internal spea
1. Connect your microphone to the Microphone connector on the ARD9900. (Note: The microphone cable to the radio MUST be un
Code Setting Master Key code setting The master key code is a password to allow the authorised operator access to the system management set
Channel Switch Setting There are 16 different channel settings for the ARD9900. By simply rotating the channel switch on the front panel of the ARD99
values. If you wish to check detailed settings, use the ADS command in the system management mode. Typical example of channel setting entry for with
Data Communication Run a terminal software program such as Windows HyperTerminal to control the ARD9900, and enter control commands.
once will enable output of the video signal connected to the Video Input to be sent to the video output port so that the video image can be checked be
Thank you for purchasing the AOR ARD9900 Multi-mode and Digital Voice Interface. The ARD9900 is designed to convert your HF radio equipment to a mul
With reference to the points above, choose the most appropriate communication mode from the table below: Communication Selection Guidance Th
Communication Mode Setting The communication setting is set into discrete channels. [Procedure] 1. Using the AMA command, enter the Master
Example Consider setting an ID of 12345 and a NETMASK of 11100 with the digital squelch set on. The NETMASK you have set enables contact with any rem
Detailed function of communication modes [Caution: Communication mode must be set to the same for transmit and receive stations.] Mod
Mode Random Encryption mode 1 Features Communication can be made with the station that has Flag 40 or Flag 50. (The Master key and algorithm must
Mode Random Encryption Mode 4 Features Communication can be made with the station that has Flag 40 or Flag 50. (The Master key and algorithm must b
cmd>CCC_NN [CR] CCC: Command (Must be in upper case) _ Space NN: Parameter [CR]: Carriage Return Entering a command without
Operator’s Command List Command Function AAQ Send VIDEO In signal to VIDEO OUT (to a monitor screen) Capture image into memory of the ARD9900 ACD
ACO Function Enter the Converse mode Default None Format ACO [CR] Parameter None Details Change from the command mode (displaying [cmd>] on the s
ATX Function Send digital image Default None Format ATX [CR] Parameter None Details An image must be captured and stored into memory before it c
Features: Digital voice communications using existing analogue 2 way radios with encryption capability. The ARD9900 uses the same audio frequenci
Command List for the System Manager Note: 1. The following commands are available under the system management screen only.
ACP Function Set the transmit channel Default CH : X ID : 00000 NM : 00000 MD : 0 X : The current selected channel Format ACP _ {00000 – 9
ADC Function Display the current commands Default None Format ADC [CR] Parameter None Details Display the current commands Example ADC [CR] ADS
AMS Function Change the master code key Default 123456789012 Format AMS_ {000000000000 – 999999999999} [CR] Parameter 000000000000 - 99999999999
AUI Function Set user ID Default 77777 Format AUI_{00000 – 99999} [CR] Parameter 00000 – 99999 Details Set user ID. The user ID is used
Specifications OFDM Band Width: 300 Hz ~ 2.5 KHz, 36 carrier Symbol Rate 20 mS (50 Baud) Guard Interval 4 mS Tone Space 62.5 Hz Modulation Met
AOR, LTD. 2-6-4, Misuji, Taito-Ku Tokyo 111-0055, Japan Phone: 81 3 3865 1695 Fax: 81 3 3865 1697 http://www.aorja.com e-mail: post@aor
Precautions To prevent fire, personal injury, or damage to the unit, please observe the following precautions: Do not attempt to adjust the unit u
Table of Contents Page Supplied and optional accessories 1 Controls and functions 5 Front Panel 5 Rear Panel
Controls and functions Front Panel a. Power on/off switch b. TX switch This switch performs two functions: 1. In the Di
command (AVT_OFF) using the PC because the TX switch then activates a sequential function of capturing and transmitting the data. . e. Speaker volume
7. MIC GND ---------------- Microphone ground signal. 8. MIC IN -------------------- Microphone signal input. Rear Panel k. Com
Pin number Signal Details 1 MIC GND Microphone ground 2 MIC OUT Microphone Output 3 PTT PTT (Push To Talk) output 4 GND PTT ground 5 NC No
Comments to this Manuals