The normal position for the AR5001D RF gain control is fully counterclockwise when set at its most
sensitive. As the control is rotated clockwise, the S-meter will advance to indicate what strength signal is
required to produce solid and readable results.
The control is most useful on SSB most where RF gain should be adjusted so that the peaks of SSB
signals just deflect the S-meter. This will greatly reduce the level of background noise especially during
pauses in speech or inactivity.
Note: RF gain control is not available in FM mode.
Before using the RF gain control, the AGC must be set to off.
To activate RF gain control, press the [FUNC] key, and then press the [6] key.
To change RF gain, rotate the squelch knob.
To de-activate RF gain, repeat above steps.
12 PC CONTROL
12-1 USB INTERFACE
The USB (type B) connector is designed to connect directly to the USB port of a PC.
All functions of the AR5001D can be controlled by a PC by means of the USB interface.
12-1-1 USB DRIVER
Before connecting the AR5001D to a PC, the USB driver for the AR5001D needs to be installed.
The USB driver can be downloaded from the manufacturer’s website. (Shown Below)
http://www.ftdichip.com/ftdrivers.htm
Click “VCP Drivers”, then select the device name “FT232B”.
The following are the specifications for the communication protocol.
Communication speed: 115,200 bps (default), 57,600 bps, 38,400 bps, 19,200 bps, 9,600 bps
Data: 8 bit
Stop bit: 1
Parity: None
Flow control: None or RTS/CTS
Echo: Off
Return Code: (PC AR5001D): <CR><0x0d> <LF> ignore
Return Code: (AR5001D PC): <CR><LF>(0x0d, 0x0a)
Refer to the AR5001D control command list for details for PC control.