FFT frequency step
Threshold level (signal detection level)
FFnn FSnn FT-nnn FF
LC
FFnn Search bank (two digits) select to access.
nn: 00 ~ 39 (default: 00)
FSnn Frequency step select
nn: 00 ~ 10
00: 5kHz
01: 6.25kHz
02: 8.33kHz
03: 9kHz
04: 10kHz
05: 12.5kHz
06: 20kHz (default)
07: 25kHz
08: 30kHz
09: 50kHz
10: 100kHz
FT-nnn Set the threshold level. Once set, only signals over
this level will be detected by the FFT search.
-nnn: (dB) (default: -80) (dB)
LCn n: 0, 1
0: Disable search result frequency report
1: Enable search result frequency report
(Note: The FS, FT commands cannot be used alone.
They must always be used in conjunction with the FF command.)
4-4 Memory channel
The AR2300 features 2,000 memory channels (50 channels in each of the 40 banks).
The number of memory banks can be reconfigured between 5 ~ 95 (in 5 incremental).
4-4-1 Memory read mode
MR
MRnnmm nn: 00 ~ 39 (Memory bank) (default: 00)
mm: 00 ~ 49 (Memory channel) (default: 00)
ZK Go to next memory channel
ZJ Go to previous memory channel
To read: MRnnmm<CR>