6-6 Marker frequency
6-6-1 Marker frequency setup
KF
KFnnnn.nnnnnn: nnnn.nnnmmm (MHz)
(default: 0082.500000) (MHz)
The entered value may be changed according to the frequency span and
frequency range.
To read: KF<CR>
Response: KFnnnn.nnnnnn –mmm -mmm: signal level (in dB)
6-6-2 Marker frequency/ level auto output
KC
KCn n: 0, 1
0: Disable data output (default)
1: Enable data output
To read: KC<CR>
Response: MKnnnn.nnnnnn –mmm -mmm: signal level (in dB)
6-6-3 Transfer the marker frequency to receive frequency
KG
KG
(Direct command)
6-7 Spectrum data output
GL
Output the level data of each frequency on the screen.
GL<CR><LF>/<SP><CR><LF>
(Note: The separator (/<CR><LF>) has 160 lines.
To read: GL<CR>
Response: GL<CR><LF>/<SP><CR><LF>
6-8 High speed spectrum data output
FD
Output the level data of each frequency on the screen in high speed.
Convert the signal strength data of one horizontal dot into 1 byte character. Then
repeat this step for a total of 160 characters and output these data followed by
the OK response (<SP><CR><LF>).
To convert the output data to a signal strength level, subtract 0x20 (in
hexadecimal), then add -100dB.
FD<SP><CR><LF>
To read: FD<CR>
Response: FD<SP><CR><LF>