double sided tape to hold the filter in an upside down position before making the soldered
connections.
Careful examination of the PCB around the filter
connections will show that there are two 33pF SMD
capacitors connected between the filter in/out and earth. Ideally these could be removed to
give a flatter frequency response along with changing R173 to 1k8. In practice however you
will probably not notice any change and we recommend that they are left as standard. The
circuit is shown below
After fitting the filter, refer to page 68 and 69 of the AR5000 instruction manual in order to
register the new filter. You must register the new filter as a 500Hz filter - this is also the
bandwidth that will be displayed when the filter is selected. Unfortunately there is no 1kHz
bandwidth available on the display.
AR5000 DETECTOR OUTPUT
The AR5000 is capable of running various decoders from its ACC1 socket on the front panel
(pin2 gives approx. 180mV RMS -100Kohm).
This is suitable in most cases, but is slightly limited by two 0.1uf capacitors and switching
circuits in line between the detector output and the socket.
If problems are experienced, then the solution will probably be direct connection to the FM
detector IC on the IF unit.
To do this, remove the top case of the receiver to reveal the IF and PLL units underneath. The
IF unit is the rearmost board (fitted with various filters). Once the six screws are undone and
the IF OUT mini-coax plug disconnected, the board will pull slightly forward and hinge
towards the front panel.